EV Car Fire Blanket(6x9m/8x10m-1000Degree)
Specially modified glass fibre fabric with fire resistant silicone coating to both sides.
4 x heavy-duty, fire resistant pull handles to corners with triple layer reinforced mounting points.
All seams and handles stitched with high temperature resistant thread.
Dimensions: 9 x 6 metres – Weight: c.28kg (includes storage bag).
| Property | Units | Value | Tolerance |
|---|---|---|---|
| Weight | g/m2 | 420+100 | ± 5% |
| Silicone Coating | g/m2 | 50 (each side) | ± 10% |
| Tensile Strength – Warp | N | 1400 | ± 2% |
| Tensile Strength – Weft | N | 1000 | ± 2% |
| Tear Strength | N | >128 | ± 2% |
| Burst Strength | kPa | >1000 | ± 4% |
Base MaterialTest Data:
BS 476: Part 7: 1997 : Surface Spread of Flame – Compliant
BS 476: Part 6: 1989 + A1:2009 : Fire Propagation Index – Compliant
Based on the above test results the product is deemed as meeting a CLASS 0 RATING for fire resistance.
This is similar to the CLASS A fire resistance rating in the USA.
BS 476-20/22 1987 (similar to USA standard ASTM E119) : Indicative Furnace Test – Resisted 1,000°C (1,832°F) for 90 minutes, at which point the test was stopped.
D6413 / D6413M-22 : USA standard for Vertical Flame Resistance – PASSED with Best Possible Result.
NFPA 701 : USA standard for Flame Propagation of Textiles – PASSED and NFPA certified.
ISO EN 13501-1 2018 : European Standard for Fire Classification of Products – Rating: A2, s1, d0
Additional Tests by Intertek Testing Services (UK) Ltd – average results
| BS EN ISO 14419:2010 | Hydrocarbon Resistance | 7 |
| BS EN ISO 9237:1995 | Air Permeability @ 20°C | 0.22 mm/s |
| BS EN ISO 9237:1995 | Air Permeability @ 400°C | 0.63 mm/s |
| BS EN ISO 13934-1:2013 | Tensile Properties 1 Hr @ 400°C | Warp ~ 1156.6N Weft ~ 1012.5N |
| BS EN 20811:1992/ISO 811:1981 | Hydrostatic Pressure Test – cm/H2O (Mbar) | 492 |
The EV Fire Blanket was deployed over a burning Nissan Leaf that was in an advanced stage of Thermal Runaway. The fire temperature dropped rapidly from over 900°C to 47°C in under 10 minutes.
Contact: Johnson
Phone: 136 3296 8671
E-mail: sunwindfire@foxmail.com